Skip to product information
1 of 7

25LB R407A (R-407A) Refrigerant Gas | 30 Cylinders

25LB R407A (R-407A) Refrigerant Gas | 30 Cylinders

Regular price $260.00 USD
Regular price Sale price $260.00 USD
Sale Sold out
Shipping calculated at checkout.
Quantity
Quantity

I confirm this refrigerant will be resold or installed by an EPA certified technician, and I will comply with all applicable regulations.

Amazon American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Delivery Policy

Orders are usually processed within 24 hours. Standard delivery usually takes 2-5 business days after shipment. Orders placed on Friday may be delayed. Weekend orders are processed on business days only.

Ask a Question

R407A is a blended HFC refrigerant used mainly in low- and medium-temperature commercial refrigeration systems. It has been positioned as a non-ozone-depleting replacement option for R22 in compatible refrigeration equipment and is commonly associated with retrofit and service use in approved commercial systems. It remains relevant where operators need continued maintenance and support for existing refrigeration equipment designed or adapted for R407A operation.

View full details
Expert Refrigerant Solutions Reliable
High-Performance Cooling

Key Specifications

This R407A refrigerant cylinder is designed for compatible commercial refrigeration systems using R407A for retrofit, service, and maintenance applications.

Chemical name / composition: R32/R125/R134a (20/40/40 wt%)

Chemical formula: CH2F2 / C2HF5 / C2H2F4

Molecular weight: 90.11

Boiling point: Approx. -45.0°C

Liquid density at 25°C: 1145 kg/m³

Critical temperature: 83.2°C

Critical pressure: 4.52 MPa abs

Safety class: A1, non-flammable

GWP (AR4): 2107

ODP: 0

Typical applications: Medium- and low-temperature commercial refrigeration; retrofit alternative to R22 and R404A

Approx. cylinder size: 16.5 in height × 9.8 in width

Mouth width: 6.3 in

Net weight: 25 lbs (11.3 kg)

Product Features

Pressure-Resistant Cylinder: The cylinder is built with a pressure-resistant structure to support stable handling during transportation, storage, and routine service use. This design helps reduce the risk of deformation caused by external pressure.

Corrugated Outer Box: A corrugated outer box provides extra protection during shipping and warehousing. It helps reduce scratches, dents, and other surface damage while the product is being moved or stacked.

Protective Packaging: Leak-resistant and crush-resistant packaging gives the cylinder added protection in transit. This helps the product arrive in better condition and lowers the risk of avoidable shipping damage.

25 lb Net Weight: Net weight 25 lbs (11.3 kg), suitable for compatible existing systems that require R407A for service and maintenance.

Self-Sealing Valve: The self-sealing valve design supports safer storage and easier handling. It helps reduce the chance of unintended leakage during storage or service preparation.

Protective Top Collar: The top collar helps shield the valve area from impact during movement and storage, making the cylinder easier to handle and better protected overall.

Usage Scenarios

Commercial Refrigeration: R407A is commonly used in compatible commercial refrigeration systems, including display cases, freezers, and similar equipment where low- and medium-temperature cooling performance is required.

Retrofit for R404A Systems: R407A is also used in certain compatible retrofit projects where older R404A refrigeration systems are being converted for continued service. In these applications, actual suitability depends on system design, lubricant requirements, and operating conditions.

Medium Temperature Cooling: In compatible medium-temperature cooling systems, R407A may be used where operators need refrigeration performance in equipment approved for this refrigerant. It is typically applied in systems specifically selected or adjusted for R407A service.

These are common examples of where R407A may be used. Actual use depends on system design, operating conditions, lubricant compatibility, and refrigerant approval. Buyers should always confirm that their equipment is suitable for R407A before purchase or use.

Professional Use

R407A is commonly used in professional service work for low- and medium-temperature commercial refrigeration systems where this refrigerant is specified or approved for use. In many retrofit and service situations, it is selected as an alternative for certain systems previously using R22 or R404A.

In actual service scenarios, R407A is typically handled during maintenance, repair work, and refrigerant-related procedures on compatible commercial refrigeration equipment. This is most common where the system design, operating conditions, lubricant requirements, and retrofit guidelines are confirmed before service begins.

Because R407A is a zeotropic HFC blend, proper handling during service is still important. Using correct tools, following approved charging procedures, and confirming manufacturer requirements before work begins can help support proper refrigerant composition and more dependable system performance.

This product is generally intended for use in equipment specifically designed for R407A or properly approved for compatible retrofit use, and is typically handled by qualified technicians. Buyers should always confirm system requirements, refrigerant compatibility, and applicable service practices before purchase or use.

Frequently Asked Questions

Can I return or exchange this product?

Because this is a chemical product, returns or exchanges are not accepted after shipment unless there is a confirmed quality issue or visible packaging damage upon delivery. To help protect product integrity and comply with handling requirements, we do not accept returns or exchanges for items that arrive in normal condition. Please review product specifications and compatibility carefully before placing your order.

What should I do if the package arrives damaged or the product is not usable?

If the package arrives with visible shipping damage, or if the product is damaged and cannot be used properly upon arrival, please contact us promptly after delivery. Please provide clear photos of the outer packaging, shipping label, and the product itself so the issue can be reviewed. After confirmation, we will provide an appropriate solution based on the actual condition of the order.

How fast is shipping, and how reliable is the delivery service?

Orders are typically shipped within 24 business hours on business days. Shipments are sent via FedEx, a widely used carrier known for efficient and reliable delivery service. Delivery times may vary depending on the destination and local carrier operations.

Why does the shipping label show a different weight from the product weight?

The weight shown on the shipping label may sometimes be slightly lower than the actual product weight due to shipping documentation processing. There is no need to worry. This does not affect the product you receive or require any additional payment. The cylinder you receive reflects the actual product weight.

How should this product be stored?

This product should be stored in a cool, dry, and well-ventilated area, away from direct sunlight and heat sources. The cylinder should be kept upright, properly secured during storage and transportation, and handled carefully to avoid physical damage. Always follow the product label instructions and applicable local storage and safety regulations.

What is R407A, and what systems is it commonly used in?

R407A is a blended HFC refrigerant commonly used in medium- and low-temperature commercial refrigeration systems. It is often used in commercial refrigeration, transport refrigeration, and some industrial refrigeration applications, especially in equipment designed for or approved for R407A service.